Advertisement
Original Research Article| Volume 23, P74-79, July 2022

Download started.

Ok

Intrafraction motion during radiotherapy of breast tumor, breast tumor bed, and individual axillary lymph nodes on cine magnetic resonance imaging

Open AccessPublished:July 08, 2022DOI:https://doi.org/10.1016/j.phro.2022.06.015

      Highlights

      • Intrafraction motion of the breast and individual axillary lymph nodes was studied.
      • Displacements were investigated using cine magnetic resonance imaging.
      • Motion was separated into breathing and drift components.
      • Medians of the maximum displacements were small, <3 mm for breast and lymph nodes.
      • Intrafraction motion of the tumor (bed) was less in prone than in supine position.

      Abstract

      Background and purpose

      In (ultra-)hypofractionation, the contribution of intrafraction motion to treatment accuracy becomes increasingly important. Our purpose was to evaluate intrafraction motion and resulting geometric uncertainties for breast tumor (bed) and individual axillary lymph nodes, and to compare prone and supine position for the breast tumor (bed).

      Materials and methods

      During 1–3 min of free breathing, we acquired transverse/sagittal interleaved 1.5 T cine magnetic resonance imaging (MRI) of the breast tumor (bed) in prone and supine position and coronal/sagittal cine MRI of individual axillary lymph nodes in supine position. A total of 31 prone and 23 supine breast cine MRI (in 23 women) and 52 lymph node cine MRI (in 24 women) were included. Maximum displacement, breathing amplitude, and drift were analyzed using deformable image registration. Geometric uncertainties were calculated for all displacements and for breathing motion only.

      Results

      Median maximum displacements (range over the three orthogonal orientations) were 1.1–1.5 mm for the breast tumor (bed) in prone and 1.8–3.0 mm in supine position, and 2.2–2.4 mm for lymph nodes. Maximum displacements were significantly smaller in prone than in supine position, mainly due to smaller breathing amplitude: 0.6–0.9 mm in prone vs. 0.9–1.4 mm in supine. Systematic and random uncertainties were 0.1–0.4 mm in prone position and 0.2–0.8 mm in supine position for the tumor (bed), and 0.4–0.6 mm for the lymph nodes.

      Conclusion

      Intrafraction motion of breast tumor (bed) and individual lymph nodes was small. Motion of the tumor (bed) was smaller in prone than in supine position.

      Graphical abstract

      Keywords

      1. Introduction

      Accelerated partial breast irradiation (APBI) is increasingly used to treat breast cancer patients, reducing the number of treatment fractions down to ten, five or even one [

      Meattini I, Marrazzo L, Saieva C, Desideri I, Scotti V, Simontacchi G, et al. Accelerated Partial-Breast Irradiation Compared With Whole-Breast Irradiation for Early Breast Cancer: Long-Term Results of the Randomized Phase III APBI-IMRT-Florence Trial. J Clin Oncol 2020;38:JCO.20.00650. 10.1200/jco.20.00650.

      ,
      • Coles C.E.
      • Griffin C.L.
      • Kirby A.M.
      • Titley J.
      • Agrawal R.K.
      • Alhasso A.
      • et al.
      Partial-breast radiotherapy after breast conservation surgery for patients with early breast cancer (UK IMPORT LOW trial): 5-year results from a multicentre, randomised, controlled, phase 3, non-inferiority trial.
      ,
      • Bosma S.C.J.
      • Leij F.
      • Vreeswijk S.
      • de Maaker M.
      • Wesseling J.
      • van de Vijver M.
      • et al.
      Five-Year Results of the Preoperative Accelerated Partial Breast Irradiation (PAPBI) Trial.
      ,
      • Horton J.K.
      • Blitzblau R.C.
      • Yoo S.
      • Geradts J.
      • Chang Z.
      • Baker J.A.
      • et al.
      Preoperative Single-Fraction Partial Breast Radiation Therapy: A Novel Phase 1, Dose-Escalation Protocol With Radiation Response Biomarkers.
      ,
      • Guidolin K.
      • Yaremko B.
      • Lynn K.
      • Gaede S.
      • Kornecki A.
      • Muscedere G.
      • et al.
      Stereotactic image-guided neoadjuvant ablative single-dose radiation, then lumpectomy, for early breast cancer: the SIGNAL prospective single-arm trial of single-dose radiation therapy.
      ,
      • Nichols E.
      • Kesmodel S.B.
      • Bellavance E.
      • Drogula C.
      • Tkaczuk K.
      • Cohen R.J.
      • et al.
      Preoperative Accelerated Partial Breast Irradiation for Early-Stage Breast Cancer: Preliminary Results of a Prospective, Phase 2 Trial.
      ,
      • Vasmel J.E.
      • Charaghvandi R.K.
      • Houweling A.C.
      • Philippens M.E.P.
      • van Asselen B.
      • Vreuls C.P.H.
      • et al.
      Tumor Response After Neoadjuvant Magnetic Resonance Guided Single Ablative Dose Partial Breast Irradiation.
      ]. With (ultra-)hypofractionation, the dose per treatment fraction and therefore delivery time increases. Consequently, the relative contribution of intrafraction motion to dose delivery uncertainties becomes increasingly important.
      Position verification and correction after setup for APBI is usually performed using cone beam computed tomography. Displacements occurring after this initial correction are not corrected for and have to be considered in planning target volume (PTV) margins. Applying small, but adequate, margins is desirable to keep the irradiated volume as small as possible. Yet, what margin to apply is not well known for APBI.
      To determine adequate margins, we need to quantify intrafraction displacements. Available studies on intrafraction motion required one or more fiducial markers [
      • Mouawad M.
      • Lailey O.
      • Poulsen P.
      • O’Neil M.
      • Brackstone M.
      • Lock M.
      • et al.
      Intrafraction motion monitoring to determine PTV margins in early stage breast cancer patients receiving neoadjuvant partial breast SABR.
      ,
      • Zhen X.
      • Zhao B.
      • Wang Z.
      • Timmerman R.
      • Spangler A.
      • Kim N.
      • et al.
      Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation.
      ,
      • Hoekstra N.
      • Habraken S.
      • Swaak-Kragten A.
      • Hoogeman M.
      • Pignol J.P.
      Intrafraction motion during partial breast irradiation depends on treatment time.
      ] or used surrogate structures for motion tracking, such as the sternum or body surface [
      • Mitchell J.
      • Formenti S.C.
      • DeWyngaert J.K.
      Interfraction and Intrafraction Setup Variability for Prone Breast Radiation Therapy.
      ,
      • Reitz D.
      • Carl G.
      • Schönecker S.
      • Pazos M.
      • Freislederer P.
      • Niyazi M.
      • et al.
      Real-time intra-fraction motion management in breast cancer radiotherapy: Analysis of 2028 treatment sessions.
      ,
      • Jensen C.A.
      • Acosta Roa A.M.
      • Lund J.-Å.
      • Frengen J.
      Intrafractional baseline drift during free breathing breast cancer radiation therapy.
      ,
      • Veldeman L.
      • De Gersem W.
      • Speleers B.
      • Truyens B.
      • Van Greveling A.
      • Van Den Broecke R.
      • et al.
      Alternated prone and supine whole-breast irradiation using IMRT: Setup precision, respiratory movement and treatment time.
      ]. Also, often the temporal resolution of tracking, mostly using kV imaging or portal imaging, was limited. Cine magnetic resonance imaging (MRI) provides the opportunity to evaluate intrafraction motion of the target without the need of a surrogate tracking structure or fiducial markers and provides good temporal resolution, without additional imaging dose [

      Bjerre T, Crijns S, af Rosenschöld PM, Aznar M, Specht L, Larsen R, et al. Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes. Phys Med Biol 2013;58:4943–50. 10.1088/0031-9155/58/14/4943.

      ,
      • Seregni M.
      • Paganelli C.
      • Lee D.
      • Greer P.B.
      • Baroni G.
      • Keall P.J.
      • et al.
      Motion prediction in MRI-guided radiotherapy based on interleaved orthogonal cine-MRI.
      ,
      • van Heijst T.C.F.
      • Philippens M.E.P.P.
      • Charaghvandi R.K.
      • den Hartogh M.D.
      • Lagendijk J.J.W.W.
      • Desirée van den Bongard H.J.G.
      • et al.
      Quantification of intra-fraction motion in breast radiotherapy using supine magnetic resonance imaging.
      ,
      • Bruijnen T.
      • Stemkens B.
      • Terhaard C.H.J.
      • Lagendijk J.J.W.
      • Raaijmakers C.P.J.
      • Tijssen R.H.N.
      Intrafraction motion quantification and planning target volume margin determination of head-and-neck tumors using cine magnetic resonance imaging.
      ].
      Patients receiving APBI may be treated in prone or supine position. Few studies compared intrafraction motion between both positions, but only evaluated respiratory amplitude and not evolvement of displacement over time [
      • Veldeman L.
      • De Gersem W.
      • Speleers B.
      • Truyens B.
      • Van Greveling A.
      • Van Den Broecke R.
      • et al.
      Alternated prone and supine whole-breast irradiation using IMRT: Setup precision, respiratory movement and treatment time.
      ,
      • Morrow N.V.
      • Stepaniak C.
      • White J.
      • Wilson J.F.
      • Li X.A.
      Intra- and Interfractional Variations for Prone Breast Irradiation: An Indication for Image-Guided Radiotherapy.
      ,
      • Lakosi F.
      • Gulyban A.
      • Janvary L.
      • Simoni S.B.M.
      • Jansen N.
      • Seidel L.
      • et al.
      Respiratory Motion, Anterior Heart Displacement and Heart Dosimetry: Comparison Between Prone (Pr) and Supine (Su) Whole Breast Irradiation.
      ,
      • Kirby A.M.
      • Evans P.M.
      • Helyer S.J.
      • Donovan E.M.
      • Convery H.M.
      • Yarnold J.R.
      A randomised trial of Supine versus Prone breast radiotherapy (SuPr study): comparing set-up errors and respiratory motion.
      ]. For axillary lymph nodes, evaluations of intrafraction motion are limited to center-of-mass displacements of lymph nodes levels between different breathing phases or for deep-inspirational breath-hold [
      • Moran J.M.
      • Balter J.M.
      • Ben-David M.A.
      • Marsh R.B.
      • van Herk M.
      • Pierce L.J.
      The short-term displacement and reproducibility of the breast and nodal targets under active breathing control.
      ,
      • Qi X.S.
      • White J.
      • Rabinovitch R.
      • Merrell K.
      • Sood A.
      • Bauer A.
      • et al.
      Respiratory Organ Motion and Dosimetric Impact on Breast and Nodal Irradiation.
      ,
      • Borm K.J.
      • Oechsner M.
      • Combs S.E.
      • Duma M.N.
      Deep-Inspiration Breath-Hold Radiation Therapy in Breast Cancer: A Word of Caution on the Dose to the Axillary Lymph Node Levels.
      ,
      • Pazos M.
      • Fiorentino A.
      • Gaasch A.
      • Schönecker S.
      • Reitz D.
      • Heinz C.
      • et al.
      Dose variability in different lymph node levels during locoregional breast cancer irradiation: the impact of deep-inspiration breath hold.
      ]; therefore they do not provide relevant measurements for boost treatment of individual lymph nodes.
      In this study, we used cine MRI to evaluate intrafraction motion of the breast tumor or tumor bed and of individual axillary lymph nodes to determine the geometric uncertainties for (ultra-)hypofractionated treatment on either a conventional linac or an MR-Linac. For the breast, we compared prone and supine position.

      2. Methods and materials

      2.1 Patients

      Between December 2016 and February 2020, 48 women with invasive breast cancer or ductal carcinoma in situ gave written informed consent for participation in this MRI study (Table 1). The study was approved by the institutional review board of the University Medical Center Utrecht (trial number NL56683.041.16). All women were referred to the radiotherapy department for preoperative and/or postoperative consultation for adjuvant radiotherapy. Thirty-three women participated prior to any treatment and 14 women participated during adjuvant radiotherapy. Twenty-three patients participated in the breast subgroup and 24 patients in the lymph nodes subgroup. One patient was not scanned because of anxiety.
      Table 1Patient characteristics.
      All



      (n = 47)
      MRI breast



      (n = 23)
      MRI lymph nodes



      (n = 24)
      Age (median [range]) (years)58 (26–78)54 (26–72)62 (42–78)
      BMI (median [range]) (kg/m2)25.6 (20.2–45.9)24.7 (20.2–36.5)25.8 (20.8–45.9)
      Timing of MRI
      Preoperative33 (69%)14 (61%)19 (76%)
      Postoperative15 (31%)9 (39%)6 (24%)
      Tumor side•
      Left25 (50%)10 (43%)15 (56%)
      Right25 (50%)13 (57%)12 (44%)
      Tumor stage*
      T03 (6%)1 (4%)2 (7%)
      Tis7 (14%)1 (4%)6 (22%)
      T124 (48%)13 (57%)11 (41%)
      T215 (30%)8 (35%)7 (26%)
      T31 (2%)0 (0%)1 (4%)
      Nodal stage*
      N039 (78%)17 (74%)22 (81%)
      N14 (8%)3 (13%)1 (4%)
      N21 (2%)1 (4%)0 (0%)
      N32 (4%)0 (0%)2 (7%)
      Regional recurrence1 (2%)0 (0%)1 (4%)
      No SNB performed3 (6%)2 (9%)1 (4%)
      •Two patients had bilateral breast cancer.
      *Tumor stage and nodal stage present cT and cN stage for preoperative patients and (y)pT and (y)pN stage for postoperative patients.
      BMI: body mass index; SNB: sentinel node biopsy.

      2.2 Patient positioning and imaging

      All patients underwent 1.5 T MRI (Ingenia, Philips, the Netherlands). The breast subgroup was scanned in prone and supine position, except for one woman who was scanned only in supine position and two women who were scanned only in prone position. The lymph nodes subgroup was scanned only in supine position. More details on patient setup are described in our previous study [

      Groot Koerkamp ML, van der Leij F, van ’t Westeinde T, Bol GH, Scholten V, Bouwmans R, et al. Prone vs. supine accelerated partial breast irradiation on an MR-Linac: A planning study. Radiother Oncol 2021; 165: 193–9. 10.1016/j.radonc.2021.11.001.

      ]. In supine position, all women were positioned on the ThoraxSupportTM (MacroMedics, The Netherlands) without inclination with both arms in abduction. A 16-elements anterior coil, mounted on coil bridges to prevent breast deformation, and the posterior coil integrated in the scanner table were used as receive coils. In prone position, the women were positioned on an in-house developed support (in collaboration with Orfit Industries, Belgium). The ipsilateral breast was hanging freely, and the contralateral breast was pulled aside. Two flexible surface coils, one on each side of the ipsilateral breast, and the posterior coil were used as receive coils. In the last 13 patients, the anterior coil was additionally placed on top of the patient when in-bore space was sufficient (8/13 patients).
      All patients underwent two or three MRI sessions with repositioning in between, acquired on a single day (40 patients) or on different days (7 patients). Median duration of each session was 20 min (range: 7–35 min). In each session, a 1–3 min free-breathing cine MRI was acquired on average 15 min (range: 6–32 min) after start of imaging. We acquired 63 cine pairs of the breast and 63 cine pairs of the lymph nodes.
      To investigate displacements along the three main axes, the cine MRI were acquired interleaved in two planes: transverse/sagittal for the breast subgroup and coronal/sagittal for the lymph nodes subgroup. The intersection between the planes was positioned through the breast tumor or tumor bed for the breast subgroup and through one axillary lymph node for the lymph nodes subgroup. This was planned on a 3D T1-weighted MRI acquired before the cine MRI. The cine MRI was acquired using a 2D gradient echo sequence, except for four cines that were acquired with a balanced steady-state free precession (SSFP) sequence. Scan parameters for the majority (>90%) of the cines were: repetition time/echo time = 2.8–2.9/1.4 ms, in-plane field-of-view = 350-450×350-500 mm2, slice thickness = 8 mm, flip angle = 10° (35° for balanced SSFP), acquired pixel size 1.8–2.0x1.8–2.0 mm2, reconstructed pixel size 1.6–1.7x1.6–1.7 mm2, sensitivity encoding of 1–1.2, and a scan interval of 0.6 s per cine, i.e. 1.2 s per orthogonal cine pair (one pair = coronal/sagittal or transverse/sagittal). For the remaining minority, all in the breast subgroup and mostly due to scanning challenges in prone position, the field-of-view was reduced down to 280x280 mm2, reconstructed voxels size ranged 1.1–2.0×1.1–2.0 mm2, and scan interval varied from 0.3 to 0.7 s. To get rid of the saturation band caused by acquisition of the orthogonal slices, occurring in every first slice acquired in a plane, all cines were acquired in reversed order for each second set of cine pairs, such that the acquisition order became transverse-sagittal-sagittal-transverse etc. for the breast cines and coronal-sagittal-sagittal-coronal etc. for the lymph node cines (Supplementary Material).

      2.3 Image processing and motion quantification

      Because of the saturation band artefact that led to inaccurate registration results, we removed every other slice for each orientation from all cine MRI (Supplementary Material), which halved the temporal resolution. To improve registration results, image contrast was enhanced and the images were resampled to double resolution and smoothed to reduce noise (Fig. 1). In each cine MRI, we manually indicated a region of interest (ROI) in one reference slice to depict the breast tumor, tumor bed or lymph node to be tracked.
      Figure thumbnail gr1
      Fig. 1Schematic overview of the image registration and motion quantification steps. Abbreviations: cor: coronal, sag: sagittal, tra: transverse, dyn: dynamic slice, LN: lymph node, ROI: region of interest.
      Next, all slices were registered to the reference slice using deformable registration with optical flow [
      • Zachiu C.
      • Denis de Senneville B.
      • Moonen C.
      • Ries M.
      A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept.
      ,
      • Zachiu C.
      • Papadakis N.
      • Ries M.
      • Moonen C.
      • Denis de Senneville B.
      An improved optical flow tracking technique for real-time MR-guided beam therapies in moving organs.
      ], resulting in pixel-wise 2D deformation vector fields. Displacement of the target was quantified by taking the mean displacement vector of all ROI-pixels. From this, we calculated the maximum displacement (Δmax), respiratory motion amplitude (Mresp), and drift displacement (Mdrift), see Fig. 1. Δmax was defined as the distance between the extreme positions of the target. A moving average with a window of 30 s was used to calculate drift motion. The moving average was used to correct the raw motion signal to obtain the motion resulting from breathing. Mresp was calculated as the distance between the 5th and 95th percentiles of the breathing trace. The extreme positions in the drift motion were taken as Mdrift. All image processing and motion quantifications steps were performed using Matlab R2019a (The MathWorks, Inc., USA).
      For the breast, we excluded 11 transverse and 9 sagittal cine series. For the lymph nodes, we excluded 10 coronal and 15 sagittal cine series. Exclusion reasons were (number of breast and lymph nodes cines respectively): the 2D image was not positioned correctly (2 and 4 cines), no clear tumor (bed) or lymph node visible (5 and 19 cines), an incorrect tracking result (13 and 2 cines).

      2.4 Statistical analysis

      Displacements were analyzed using descriptive statistics. For the subgroup of breast cine patients of whom we had both a supine and a prone cine MRI tracking result, we used a Wilcoxon signed-rank test to compare Δmax, Mresp, and Mdrift between prone and supine position (RStudio version 1.0.143, Rstudio Team, USA). In patients with multiple cine MRI of one position available, only the first acquired dataset was used for testing. A p-value < 0.05 was considered statistically significant.

      2.5 Geometric uncertainties

      To determine the geometric uncertainties resulting from the intrafraction motion, we calculated the mean and standard deviation of the raw motion traces. Subsequently, we calculated the mean of means (M), systematic error (Σ = standard deviation of means) and random error (σ = root mean squared of standard deviations).
      Additionally, we calculated the uncertainty resulting from the breathing motion only. This σresp was calculated as the root mean square of 0.4*Mresp of all cines [
      • Hoekstra N.
      • Habraken S.
      • Swaak-Kragten A.
      • Hoogeman M.
      • Pignol J.P.
      Intrafraction motion during partial breast irradiation depends on treatment time.
      ,
      • Engelsman M.
      • Sharp G.C.
      • Bortfeld T.
      • Onimaru R.
      • Shirato H.
      How much margin reduction is possible through gating or breath hold?.
      ].

      3. Results

      Fig. 2 shows examples of motion traces of the breast tumor (bed) and illustrates larger displacements in supine than in prone position (video results in Supplementary Material). In general, Δmax, Mresp and Mdrift were all larger in supine than in prone position, most obviously in anterior-posterior and superior-inferior direction (Table 2). Mdrift was somewhat larger towards anterior and superior than towards posterior and inferior, especially in supine position. In the paired comparison, Δmax was significantly larger in supine position (Fig. 3). Mresp was also significantly larger for supine position in anterior-posterior (p-value = 0.003) and superior-inferior direction (p-value < 0.001), but not in left–right direction (p-value = 0.105). Mdrift was only significantly larger in supine position for the drift in the superior direction (Mdrift,2; p-value = 0.007).
      Figure thumbnail gr2
      Fig. 2Example of motion traces in three different patients. A: sagittal cines of a patient with regular breathing motion in supine (A1) and prone (A2) position; B: transverse cine motion trace of a patient with a deep breath around 80 s in supine position, with a remaining drift in breathing level afterwards; C: transverse motion trace of a patient showing a single large motion peak around 165 s caused by bulk motion on the couch. Note that the y-axes are scaled differently for each patient.
      Table 2Motion of the breast tumor or tumor bed and individual axillary lymph nodes in cine MRI. Δmax = maximum displacement; Mresp = respiratory amplitude; Mdrift = maximum drift displacement. Mdrift,1 is towards the left (L), inferior (I) and posterior (P) direction; Mdrift,2 is towards the right (R), superior (S) and anterior (A) direction.
      ParameterLRAPSI
      Median (range)Median (range)Median (range)
      Breast (prone)# cines303131
      Δmax [mm]1.3 (0.2–3.9)1.5 (0.3–3.3)1.1 (0.1–4.6)
      Mresp [mm]0.8 (0.2–1.4)0.9 (0.3–1.8)0.6 (0.1–1.6)
      Mdrift,1 [mm]0.2 (0–2.2)0.2 (0–0.5)0.1 (0–2.4)
      Mdrift,2 [mm]0.1 (0–0.7)0.3 (0–1.8)0.2 (0–2.6)
      Breast (supine)# cines222323
      Δmax [mm]1.8 (0.8–4.2)3.0 (1.1–13.1)2.4 (1.1–7.8)
      Mresp [mm]0.9 (0.4–2.4)1.6 (0.6–4.1)1.4 (0.7–2.6)
      Mdrift,1 [mm]0.3 (0.0–1.0)0.3 (0–2.0)0.1 (0–1.5)
      Mdrift,2 [mm]0.1 (0–1.3)0.5 (0–5.3)0.5 (0–3.3)
      Lymph nodes (supine)# cines525248
      Δmax [mm]2.2 (1.1–5.3)2.4 (1.0–5.4)2.3 (0.5–5.0)
      Mresp [mm]1.4 (0.7–2.7)1.5 (0.8–3.7)1.4 (0.5–3.3)
      Mdrift,1 [mm]0.2 (0–1.9)0.1 (0–1.2)0.2 (0–1.5)
      Mdrift,2 [mm]0.2 (0–1.8)0.3 (0–2.1)0.3 (0–1.6)
      Figure thumbnail gr3
      Fig. 3Comparison of Δmax in prone vs. supine cine MRI acquired in the same patient. * = statistically significant.
      The maximum displacements of individual lymph nodes were comparable in all directions with median values ≤ 2.4 mm (Table 2). Motion was mainly due to breathing, with median drifts in all directions of maximum 0.3 mm. The largest Δmax were mostly caused by infrequent deep breaths, less often a drift occurred. In general, we observed a higher Δmax for 3 min cine MRI than for 1 min cine MRI.
      The systematic and random errors are shown in Table 3. Both uncertainties were below 0.4 mm in all directions for the breast in prone position. The uncertainties in supine position were larger and ranged up to 0.8 mm for the anterior-posterior direction. Systematic and random errors for the lymph nodes were similar in all directions, 0.4–0.6 mm.
      Table 3Geometric uncertainties for intrafraction motion on cine MRI. Mean of means (M), systematic error (Σtotal), and random error (σtotal) for all intrafraction motion and for breathing only (σresp).
      ParameterLRAPSI
      Breast (prone)M [mm]0.0−0.1−0.1
      Σtotal [mm]0.10.20.2
      σtotal [mm]0.30.40.3
      σresp [mm]0.30.40.3
      Breast (supine)M [mm]0.1−0.2−0.2
      Σtotal [mm]0.20.70.5
      σtotal [mm]0.40.80.6
      σresp [mm]0.50.80.6
      Lymph nodes (supine)M [mm]−0.1−0.0−0.1
      Σtotal [mm]0.40.40.4
      σtotal [mm]0.60.60.6
      σresp [mm]0.70.70.7

      4. Discussion

      Our results showed that intrafraction motion of the breast and axillary lymph nodes was small with median maximum displacements below 3 mm. Incidental large maximum displacements up to 13 mm were observed, but were mostly transient. Intrafraction displacements of the breast tumor (bed) were significantly smaller in prone than in supine position. In the analysis of separated drift and breathing motion, it was observed that this was mainly due to smaller breathing motion in prone position. The geometric uncertainties resulting from intrafraction displacement are small, at maximum 0.8 mm. Prone position may be favored over supine position for APBI or boost treatment because of the reduced intrafraction motion.
      Intrafraction motion has been studied before in prone and supine position, though only few studies previously compared both positions [
      • Veldeman L.
      • De Gersem W.
      • Speleers B.
      • Truyens B.
      • Van Greveling A.
      • Van Den Broecke R.
      • et al.
      Alternated prone and supine whole-breast irradiation using IMRT: Setup precision, respiratory movement and treatment time.
      ,
      • Morrow N.V.
      • Stepaniak C.
      • White J.
      • Wilson J.F.
      • Li X.A.
      Intra- and Interfractional Variations for Prone Breast Irradiation: An Indication for Image-Guided Radiotherapy.
      ,
      • Lakosi F.
      • Gulyban A.
      • Janvary L.
      • Simoni S.B.M.
      • Jansen N.
      • Seidel L.
      • et al.
      Respiratory Motion, Anterior Heart Displacement and Heart Dosimetry: Comparison Between Prone (Pr) and Supine (Su) Whole Breast Irradiation.
      ,
      • Kirby A.M.
      • Evans P.M.
      • Helyer S.J.
      • Donovan E.M.
      • Convery H.M.
      • Yarnold J.R.
      A randomised trial of Supine versus Prone breast radiotherapy (SuPr study): comparing set-up errors and respiratory motion.
      ]. Using 4D computed tomography (CT) or magnetic sensors, these studies also showed smaller breathing amplitudes in prone position. Our results confirm the smaller respiratory motion in prone position, and are similar to the 0.5–1.1 mm for prone position [
      • Veldeman L.
      • De Gersem W.
      • Speleers B.
      • Truyens B.
      • Van Greveling A.
      • Van Den Broecke R.
      • et al.
      Alternated prone and supine whole-breast irradiation using IMRT: Setup precision, respiratory movement and treatment time.
      ,
      • Lakosi F.
      • Gulyban A.
      • Janvary L.
      • Simoni S.B.M.
      • Jansen N.
      • Seidel L.
      • et al.
      Respiratory Motion, Anterior Heart Displacement and Heart Dosimetry: Comparison Between Prone (Pr) and Supine (Su) Whole Breast Irradiation.
      ,
      • Kirby A.M.
      • Evans P.M.
      • Helyer S.J.
      • Donovan E.M.
      • Convery H.M.
      • Yarnold J.R.
      A randomised trial of Supine versus Prone breast radiotherapy (SuPr study): comparing set-up errors and respiratory motion.
      ,
      • Ahn K.H.
      • Hargreaves B.A.
      • Alley M.T.
      • Horst K.C.
      • Luxton G.
      • Daniel B.L.
      • et al.
      MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation.
      ] and 0.6–3.0 mm for supine position [
      • Hoekstra N.
      • Habraken S.
      • Swaak-Kragten A.
      • Hoogeman M.
      • Pignol J.P.
      Intrafraction motion during partial breast irradiation depends on treatment time.
      ,
      • Veldeman L.
      • De Gersem W.
      • Speleers B.
      • Truyens B.
      • Van Greveling A.
      • Van Den Broecke R.
      • et al.
      Alternated prone and supine whole-breast irradiation using IMRT: Setup precision, respiratory movement and treatment time.
      ,
      • Lakosi F.
      • Gulyban A.
      • Janvary L.
      • Simoni S.B.M.
      • Jansen N.
      • Seidel L.
      • et al.
      Respiratory Motion, Anterior Heart Displacement and Heart Dosimetry: Comparison Between Prone (Pr) and Supine (Su) Whole Breast Irradiation.
      ,
      • Kirby A.M.
      • Evans P.M.
      • Helyer S.J.
      • Donovan E.M.
      • Convery H.M.
      • Yarnold J.R.
      A randomised trial of Supine versus Prone breast radiotherapy (SuPr study): comparing set-up errors and respiratory motion.
      ] earlier found. Our work contributes substantially by not only comparing breathing amplitude, but also displacement and trends over time between both positions in the same patient.
      For both prone and supine position, the average displacements we observed were smaller compared to other studies [
      • Mouawad M.
      • Lailey O.
      • Poulsen P.
      • O’Neil M.
      • Brackstone M.
      • Lock M.
      • et al.
      Intrafraction motion monitoring to determine PTV margins in early stage breast cancer patients receiving neoadjuvant partial breast SABR.
      ,
      • Zhen X.
      • Zhao B.
      • Wang Z.
      • Timmerman R.
      • Spangler A.
      • Kim N.
      • et al.
      Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation.
      ,
      • Hoekstra N.
      • Habraken S.
      • Swaak-Kragten A.
      • Hoogeman M.
      • Pignol J.P.
      Intrafraction motion during partial breast irradiation depends on treatment time.
      ,
      • Mitchell J.
      • Formenti S.C.
      • DeWyngaert J.K.
      Interfraction and Intrafraction Setup Variability for Prone Breast Radiation Therapy.
      ,
      • Acharya S.
      • Fischer-Valuck B.W.
      • Mazur T.R.
      • Curcuru A.
      • Sona K.
      • Kashani R.
      • et al.
      Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion.
      ]. Similarly, the systematic and random intrafraction errors in prone position were much smaller than the errors reported by Mouawad et al. and Lakosi et al. [
      • Mouawad M.
      • Lailey O.
      • Poulsen P.
      • O’Neil M.
      • Brackstone M.
      • Lock M.
      • et al.
      Intrafraction motion monitoring to determine PTV margins in early stage breast cancer patients receiving neoadjuvant partial breast SABR.
      ,
      • Lakosi F.
      • Gulyban A.
      • Ben-Mustapha Simoni S.
      • Viet Nguyen P.
      • Berkovic P.
      • Noël M.
      • et al.
      Feasibility evaluation of prone breast irradiation with the Sagittilt© system including residual-intrafractional error assessment.
      ]. Both the random and systematic intrafraction errors in supine position were also slightly smaller than those reported by Hoekstra et al., except for the systematic error in anterior-posterior which was comparable [
      • Hoekstra N.
      • Habraken S.
      • Swaak-Kragten A.
      • Hoogeman M.
      • Pignol J.P.
      Intrafraction motion during partial breast irradiation depends on treatment time.
      ]. The difference may be explained by the longer durations over which displacements were quantified in the other studies.
      The duration we evaluated is shorter than actual treatments –with 6–8 min beam-on time for single fraction (Volumetric-modulated arc therapy; unpublished data of [
      • Vasmel J.E.
      • Charaghvandi R.K.
      • Houweling A.C.
      • Philippens M.E.P.
      • van Asselen B.
      • Vreuls C.P.H.
      • et al.
      Tumor Response After Neoadjuvant Magnetic Resonance Guided Single Ablative Dose Partial Breast Irradiation.
      ]) or five-fraction (MR-Linac step-and-shoot intensity-modulated radiation therapy [

      Groot Koerkamp ML, van der Leij F, van ’t Westeinde T, Bol GH, Scholten V, Bouwmans R, et al. Prone vs. supine accelerated partial breast irradiation on an MR-Linac: A planning study. Radiother Oncol 2021; 165: 193–9. 10.1016/j.radonc.2021.11.001.

      ]) APBI– and is the most important limitation of this work as displacements were shown to increase with treatment duration [
      • Hoekstra N.
      • Habraken S.
      • Swaak-Kragten A.
      • Hoogeman M.
      • Pignol J.P.
      Intrafraction motion during partial breast irradiation depends on treatment time.
      ]. Also, by acquiring the cine MRI on average 15 min after start of imaging, we may have missed the largest displacements, that were found to occur in the first minutes of a treatment fraction [
      • Jensen C.A.
      • Acosta Roa A.M.
      • Lund J.-Å.
      • Frengen J.
      Intrafractional baseline drift during free breathing breast cancer radiation therapy.
      ,
      • Ricotti R.
      • Ciardo D.
      • Fattori G.
      • Leonardi M.C.
      • Morra A.
      • Dicuonzo S.
      • et al.
      Intra-fraction respiratory motion and baseline drift during breast Helical Tomotherapy.
      ]. However, when comparing to the time bin corresponding to the average time interval after which our cine MRI was acquired, our required margins for supine position would be comparable to the margins found by Hoekstra et al. for superior-inferior and anterior-posterior direction [
      • Hoekstra N.
      • Habraken S.
      • Swaak-Kragten A.
      • Hoogeman M.
      • Pignol J.P.
      Intrafraction motion during partial breast irradiation depends on treatment time.
      ]. Contrarily, the 0.7 mm margin reported by Acharya et al. for longer durations is much smaller [
      • Acharya S.
      • Fischer-Valuck B.W.
      • Mazur T.R.
      • Curcuru A.
      • Sona K.
      • Kashani R.
      • et al.
      Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion.
      ]. This was calculated by evaluating the margin necessary to cover at least 90% of the tumor bed for 90% of the time on cine MRI, which is a different evaluation approach and can therefore not be compared directly.
      Our results showed that drift displacement, especially in supine position, was somewhat larger towards anterior and superior than towards posterior and inferior, which interestingly is opposite to the direction of the systematic drift found by others [
      • Hoekstra N.
      • Habraken S.
      • Swaak-Kragten A.
      • Hoogeman M.
      • Pignol J.P.
      Intrafraction motion during partial breast irradiation depends on treatment time.
      ,
      • Jensen C.A.
      • Acosta Roa A.M.
      • Lund J.-Å.
      • Frengen J.
      Intrafractional baseline drift during free breathing breast cancer radiation therapy.
      ,
      • Ricotti R.
      • Ciardo D.
      • Fattori G.
      • Leonardi M.C.
      • Morra A.
      • Dicuonzo S.
      • et al.
      Intra-fraction respiratory motion and baseline drift during breast Helical Tomotherapy.
      ]. Most likely this difference is also related to the short time period evaluated, and could indicate that the observed largest drifts in our work are most likely due to deep breaths inducing larger displacements towards anterior and superior with respect to normal breathing. It should be noted that our drift results provide the maximum drift amplitude in each direction and not the average systematic drift.
      This is the first study investigating motion of individual lymph nodes. Available studies only reported on displacements of lymph node levels [
      • Moran J.M.
      • Balter J.M.
      • Ben-David M.A.
      • Marsh R.B.
      • van Herk M.
      • Pierce L.J.
      The short-term displacement and reproducibility of the breast and nodal targets under active breathing control.
      ,
      • Qi X.S.
      • White J.
      • Rabinovitch R.
      • Merrell K.
      • Sood A.
      • Bauer A.
      • et al.
      Respiratory Organ Motion and Dosimetric Impact on Breast and Nodal Irradiation.
      ,
      • Borm K.J.
      • Oechsner M.
      • Combs S.E.
      • Duma M.N.
      Deep-Inspiration Breath-Hold Radiation Therapy in Breast Cancer: A Word of Caution on the Dose to the Axillary Lymph Node Levels.
      ,
      • Pazos M.
      • Fiorentino A.
      • Gaasch A.
      • Schönecker S.
      • Reitz D.
      • Heinz C.
      • et al.
      Dose variability in different lymph node levels during locoregional breast cancer irradiation: the impact of deep-inspiration breath hold.
      ]. Our maximum displacements are similar to 0.2–2.2 mm center-of-mass displacements reported for axillary lymph node regions on 4D CT or comparison of exhale CT and normal breathing state CT [
      • Moran J.M.
      • Balter J.M.
      • Ben-David M.A.
      • Marsh R.B.
      • van Herk M.
      • Pierce L.J.
      The short-term displacement and reproducibility of the breast and nodal targets under active breathing control.
      ,
      • Qi X.S.
      • White J.
      • Rabinovitch R.
      • Merrell K.
      • Sood A.
      • Bauer A.
      • et al.
      Respiratory Organ Motion and Dosimetric Impact on Breast and Nodal Irradiation.
      ], which shows that the displacements we measured correspond to the magnitude of normal breathing motion. Much larger displacements of up to 14 mm in superior-inferior and 10 mm in anterior-posterior for different axillary lymph node levels were also reported [
      • Moran J.M.
      • Balter J.M.
      • Ben-David M.A.
      • Marsh R.B.
      • van Herk M.
      • Pierce L.J.
      The short-term displacement and reproducibility of the breast and nodal targets under active breathing control.
      ,
      • Borm K.J.
      • Oechsner M.
      • Combs S.E.
      • Duma M.N.
      Deep-Inspiration Breath-Hold Radiation Therapy in Breast Cancer: A Word of Caution on the Dose to the Axillary Lymph Node Levels.
      ,
      • Pazos M.
      • Fiorentino A.
      • Gaasch A.
      • Schönecker S.
      • Reitz D.
      • Heinz C.
      • et al.
      Dose variability in different lymph node levels during locoregional breast cancer irradiation: the impact of deep-inspiration breath hold.
      ], but these were found using deep-inspiration breath-hold CT. Even our largest maximum displacements of the lymph nodes, 5.4 mm, did not reach these values, showing that we did not observe very deep breaths. These results may be useful for stereotactic treatment of individual tumor-positive regional lymph nodes that cannot be surgically resected.
      Another strength of our work is that by using MRI we could directly determine the displacement of the target instead of a surrogate such as a fiducial marker or body surface. Only few other studies reported on the use of (cine) MRI to investigate intrafraction motion of the breast [
      • van Heijst T.C.F.
      • Philippens M.E.P.P.
      • Charaghvandi R.K.
      • den Hartogh M.D.
      • Lagendijk J.J.W.W.
      • Desirée van den Bongard H.J.G.
      • et al.
      Quantification of intra-fraction motion in breast radiotherapy using supine magnetic resonance imaging.
      ,
      • Ahn K.H.
      • Hargreaves B.A.
      • Alley M.T.
      • Horst K.C.
      • Luxton G.
      • Daniel B.L.
      • et al.
      MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation.
      ,
      • Acharya S.
      • Fischer-Valuck B.W.
      • Mazur T.R.
      • Curcuru A.
      • Sona K.
      • Kashani R.
      • et al.
      Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion.
      ]. The temporal resolution of cine MRI also allowed for studying the intrafraction motion on a scale of seconds, enabling distinction between drift and breathing motion.
      Besides the limited duration of the cine MRI, this work has several other limitations. First, we had to discard imaging data because of the saturation band that impeded tracking. The remaining frequency in a single orientation (every 2.4 s) may have been too low to completely cover respiratory motion. Yet, we think that over the full cine duration the combination of breathing motion and drift is accurately captured in the motion trace statistics, by using the percentiles and average values, at least for the 3 min cine MRI. For the 1 min cine MRI, the motion may be underestimated by aliasing. Second, the displacements found are around or smaller than the voxel size. However, as the applied method allows for tracking sub-voxel displacements [
      • de Senneville B.D.
      • Mougenot C.
      • Moonen C.T.W.
      Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound.
      ] and the image resolution is also the limit for manual tracking [
      • Zachiu C.
      • Denis de Senneville B.
      • Moonen C.
      • Ries M.
      A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept.
      ], we think the method was suitable to investigate breathing motion and drift. Third, the signal-to-noise ratio differed across the scans, this may have influenced the tracking accuracy. Fourth, the results could be influenced by out-of-plane plane motion. Taking into account the slice thickness and the maximum displacements observed, the impact is considered negligible. Additionally, simultaneous out-of-plane motion was captured with the interleaved orthogonal acquisition. Fifth, the majority of lymph nodes investigated were in level I, whereas lymph nodes requiring a boost are more often located in peri-clavicular levels that cannot be reached surgically. Higher level nodes were often not visible in patients with N0 stage. Finally, the visibility of individual lymph nodes was sometimes limited because of the small size and tumors or tumor beds were not always well distinguishable from surrounding breast tissue. In some patients we used biopsy marker or surgical clip artefacts as target structure in the cine.
      This work shows that the intrafraction component of motion in the breast and for individual lymph nodes is limited and results in small geometric uncertainties. However, large structural drift or bulk motion was not observed in the evaluation. It should be evaluated if displacements in prone position remain smaller than in supine position for longer durations, as baseline drifts or patient relaxation will play a larger role in margins necessary for longer fraction durations. Future work should also address comparison of interfraction displacements for both positions to be able to evaluate impact on clinical application with respect to the current PTV margins. Additionally, future studies should investigate displacements of individual lymph nodes outside axillary level I. When applying smaller margins in hypofractionated treatments with increased duration, motion monitoring and motion mitigation techniques for non-transient large displacements should be considered, for instance by online MRI-guidance with gated dose delivery or target tracking strategies [
      • Acharya S.
      • Fischer-Valuck B.W.
      • Mazur T.R.
      • Curcuru A.
      • Sona K.
      • Kashani R.
      • et al.
      Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion.
      ,
      • Liney G.P.P.
      • Whelan B.
      • Oborn B.
      • Barton M.
      • Keall P.
      MRI-Linear Accelerator Radiotherapy Systems.
      ,
      • Uijtewaal P.
      • Borman P.T.S.
      • Woodhead P.L.
      • Hackett S.L.
      • Raaymakers B.W.
      • Fast M.F.
      Dosimetric evaluation of MRI-guided multi-leaf collimator tracking and trailing for lung stereotactic body radiation therapy.
      ].
      In conclusion, intrafraction displacements of the breast tumor or tumor bed and individual axillary lymph nodes on cine MRI were small. We showed that motion consisted of regular breathing motion and drift components and we did not observe lasting bulk displacements. The displacements and geometric uncertainties for the breast tumor (bed) in superior-inferior and anterior-posterior direction were smaller for prone than for supine position because of smaller breathing motion in prone position.

      Declaration of Competing Interest

      The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

      Acknowledgement

      The authors would like to thank Fred Groen (UMC Utrecht) and Orfit Industries for the development of the prone support used.
      Data statement
      Participants of this study did not sign informed consent for public sharing of their data, therefore the research data are not available.

      Appendix A. Supplementary data

      The following are the Supplementary data to this article:

      References

      1. Meattini I, Marrazzo L, Saieva C, Desideri I, Scotti V, Simontacchi G, et al. Accelerated Partial-Breast Irradiation Compared With Whole-Breast Irradiation for Early Breast Cancer: Long-Term Results of the Randomized Phase III APBI-IMRT-Florence Trial. J Clin Oncol 2020;38:JCO.20.00650. 10.1200/jco.20.00650.

        • Coles C.E.
        • Griffin C.L.
        • Kirby A.M.
        • Titley J.
        • Agrawal R.K.
        • Alhasso A.
        • et al.
        Partial-breast radiotherapy after breast conservation surgery for patients with early breast cancer (UK IMPORT LOW trial): 5-year results from a multicentre, randomised, controlled, phase 3, non-inferiority trial.
        Lancet. 2017; 390: 1048-1060https://doi.org/10.1016/S0140-6736(17)31145-5
        • Bosma S.C.J.
        • Leij F.
        • Vreeswijk S.
        • de Maaker M.
        • Wesseling J.
        • van de Vijver M.
        • et al.
        Five-Year Results of the Preoperative Accelerated Partial Breast Irradiation (PAPBI) Trial.
        Int J Radiat Oncol Biol Phys. 2020; 106: 958-967https://doi.org/10.1016/j.ijrobp.2019.12.037
        • Horton J.K.
        • Blitzblau R.C.
        • Yoo S.
        • Geradts J.
        • Chang Z.
        • Baker J.A.
        • et al.
        Preoperative Single-Fraction Partial Breast Radiation Therapy: A Novel Phase 1, Dose-Escalation Protocol With Radiation Response Biomarkers.
        Int J Radiat Oncol Biol Phys. 2015; 92: 846-855https://doi.org/10.1016/j.ijrobp.2015.03.007
        • Guidolin K.
        • Yaremko B.
        • Lynn K.
        • Gaede S.
        • Kornecki A.
        • Muscedere G.
        • et al.
        Stereotactic image-guided neoadjuvant ablative single-dose radiation, then lumpectomy, for early breast cancer: the SIGNAL prospective single-arm trial of single-dose radiation therapy.
        Curr Oncol. 2019; 26: 1-7https://doi.org/10.3747/co.26.4479
        • Nichols E.
        • Kesmodel S.B.
        • Bellavance E.
        • Drogula C.
        • Tkaczuk K.
        • Cohen R.J.
        • et al.
        Preoperative Accelerated Partial Breast Irradiation for Early-Stage Breast Cancer: Preliminary Results of a Prospective, Phase 2 Trial.
        Int J Radiat Oncol Biol Phys. 2017; 97: 747-753https://doi.org/10.1016/j.ijrobp.2016.11.030
        • Vasmel J.E.
        • Charaghvandi R.K.
        • Houweling A.C.
        • Philippens M.E.P.
        • van Asselen B.
        • Vreuls C.P.H.
        • et al.
        Tumor Response After Neoadjuvant Magnetic Resonance Guided Single Ablative Dose Partial Breast Irradiation.
        Int J Radiat Oncol Biol Phys. 2020; 106: 821-829https://doi.org/10.1016/j.ijrobp.2019.11.406
        • Mouawad M.
        • Lailey O.
        • Poulsen P.
        • O’Neil M.
        • Brackstone M.
        • Lock M.
        • et al.
        Intrafraction motion monitoring to determine PTV margins in early stage breast cancer patients receiving neoadjuvant partial breast SABR.
        Radiother Oncol. 2021; 158: 276-284https://doi.org/10.1016/j.radonc.2021.02.021
        • Zhen X.
        • Zhao B.
        • Wang Z.
        • Timmerman R.
        • Spangler A.
        • Kim N.
        • et al.
        Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation.
        Radiat Oncol. 2017; 12: 1-8https://doi.org/10.1186/s13014-017-0889-6
        • Hoekstra N.
        • Habraken S.
        • Swaak-Kragten A.
        • Hoogeman M.
        • Pignol J.P.
        Intrafraction motion during partial breast irradiation depends on treatment time.
        Radiother Oncol. 2021; 159: 176-182https://doi.org/10.1016/j.radonc.2021.03.029
        • Mitchell J.
        • Formenti S.C.
        • DeWyngaert J.K.
        Interfraction and Intrafraction Setup Variability for Prone Breast Radiation Therapy.
        Int J Radiat Oncol Biol Phys. 2010; 76: 1571-1577https://doi.org/10.1016/j.ijrobp.2009.07.1683
        • Reitz D.
        • Carl G.
        • Schönecker S.
        • Pazos M.
        • Freislederer P.
        • Niyazi M.
        • et al.
        Real-time intra-fraction motion management in breast cancer radiotherapy: Analysis of 2028 treatment sessions.
        Radiat Oncol. 2018; 13: 1-9https://doi.org/10.1186/s13014-018-1072-4
        • Jensen C.A.
        • Acosta Roa A.M.
        • Lund J.-Å.
        • Frengen J.
        Intrafractional baseline drift during free breathing breast cancer radiation therapy.
        Acta Oncol. 2017; 56: 867-873https://doi.org/10.1080/0284186X.2017.1288924
        • Veldeman L.
        • De Gersem W.
        • Speleers B.
        • Truyens B.
        • Van Greveling A.
        • Van Den Broecke R.
        • et al.
        Alternated prone and supine whole-breast irradiation using IMRT: Setup precision, respiratory movement and treatment time.
        Int J Radiat Oncol Biol Phys. 2012; 82: 2055-2064https://doi.org/10.1016/j.ijrobp.2010.10.070
      2. Bjerre T, Crijns S, af Rosenschöld PM, Aznar M, Specht L, Larsen R, et al. Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes. Phys Med Biol 2013;58:4943–50. 10.1088/0031-9155/58/14/4943.

        • Seregni M.
        • Paganelli C.
        • Lee D.
        • Greer P.B.
        • Baroni G.
        • Keall P.J.
        • et al.
        Motion prediction in MRI-guided radiotherapy based on interleaved orthogonal cine-MRI.
        Phys Med Biol. 2016; 61: 872-887https://doi.org/10.1088/0031-9155/61/2/872
        • van Heijst T.C.F.
        • Philippens M.E.P.P.
        • Charaghvandi R.K.
        • den Hartogh M.D.
        • Lagendijk J.J.W.W.
        • Desirée van den Bongard H.J.G.
        • et al.
        Quantification of intra-fraction motion in breast radiotherapy using supine magnetic resonance imaging.
        Phys Med Biol. 2016; 61: 1352-1370https://doi.org/10.1088/0031-9155/61/3/1352
        • Bruijnen T.
        • Stemkens B.
        • Terhaard C.H.J.
        • Lagendijk J.J.W.
        • Raaijmakers C.P.J.
        • Tijssen R.H.N.
        Intrafraction motion quantification and planning target volume margin determination of head-and-neck tumors using cine magnetic resonance imaging.
        Radiother Oncol. 2019; 130: 82-88https://doi.org/10.1016/j.radonc.2018.09.015
        • Morrow N.V.
        • Stepaniak C.
        • White J.
        • Wilson J.F.
        • Li X.A.
        Intra- and Interfractional Variations for Prone Breast Irradiation: An Indication for Image-Guided Radiotherapy.
        Int J Radiat Oncol Biol Phys. 2007; 69: 910-917https://doi.org/10.1016/j.ijrobp.2007.06.056
        • Lakosi F.
        • Gulyban A.
        • Janvary L.
        • Simoni S.B.M.
        • Jansen N.
        • Seidel L.
        • et al.
        Respiratory Motion, Anterior Heart Displacement and Heart Dosimetry: Comparison Between Prone (Pr) and Supine (Su) Whole Breast Irradiation.
        Pathol Oncol Res. 2015; 21: 1051-1058https://doi.org/10.1007/s12253-015-9932-9
        • Kirby A.M.
        • Evans P.M.
        • Helyer S.J.
        • Donovan E.M.
        • Convery H.M.
        • Yarnold J.R.
        A randomised trial of Supine versus Prone breast radiotherapy (SuPr study): comparing set-up errors and respiratory motion.
        Radiother Oncol. 2011; 100: 221-226https://doi.org/10.1016/j.radonc.2010.11.005
        • Moran J.M.
        • Balter J.M.
        • Ben-David M.A.
        • Marsh R.B.
        • van Herk M.
        • Pierce L.J.
        The short-term displacement and reproducibility of the breast and nodal targets under active breathing control.
        Int J Radiat Oncol Biol Phys. 2007; 68: 541-546https://doi.org/10.1016/j.ijrobp.2007.01.028
        • Qi X.S.
        • White J.
        • Rabinovitch R.
        • Merrell K.
        • Sood A.
        • Bauer A.
        • et al.
        Respiratory Organ Motion and Dosimetric Impact on Breast and Nodal Irradiation.
        Int J Radiat Oncol Biol Phys. 2010; 78: 609-617https://doi.org/10.1016/j.ijrobp.2009.11.053
        • Borm K.J.
        • Oechsner M.
        • Combs S.E.
        • Duma M.N.
        Deep-Inspiration Breath-Hold Radiation Therapy in Breast Cancer: A Word of Caution on the Dose to the Axillary Lymph Node Levels.
        Int J Radiat Oncol Biol Phys. 2018; 100: 263-269https://doi.org/10.1016/j.ijrobp.2017.09.026
        • Pazos M.
        • Fiorentino A.
        • Gaasch A.
        • Schönecker S.
        • Reitz D.
        • Heinz C.
        • et al.
        Dose variability in different lymph node levels during locoregional breast cancer irradiation: the impact of deep-inspiration breath hold.
        Strahlenther Onkol. 2019; 195: 13-20https://doi.org/10.1007/s00066-018-1350-y
      3. Groot Koerkamp ML, van der Leij F, van ’t Westeinde T, Bol GH, Scholten V, Bouwmans R, et al. Prone vs. supine accelerated partial breast irradiation on an MR-Linac: A planning study. Radiother Oncol 2021; 165: 193–9. 10.1016/j.radonc.2021.11.001.

        • Zachiu C.
        • Denis de Senneville B.
        • Moonen C.
        • Ries M.
        A framework for the correction of slow physiological drifts during MR-guided HIFU therapies: Proof of concept.
        Med Phys. 2015; 42: 4137-4148https://doi.org/10.1118/1.4922403
        • Zachiu C.
        • Papadakis N.
        • Ries M.
        • Moonen C.
        • Denis de Senneville B.
        An improved optical flow tracking technique for real-time MR-guided beam therapies in moving organs.
        Phys Med Biol. 2015; 60: 9003-9029https://doi.org/10.1088/0031-9155/60/23/9003
        • Engelsman M.
        • Sharp G.C.
        • Bortfeld T.
        • Onimaru R.
        • Shirato H.
        How much margin reduction is possible through gating or breath hold?.
        Phys Med Biol. 2005; 50: 477-490https://doi.org/10.1088/0031-9155/50/3/006
        • Ahn K.H.
        • Hargreaves B.A.
        • Alley M.T.
        • Horst K.C.
        • Luxton G.
        • Daniel B.L.
        • et al.
        MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation.
        Int J Radiat Oncol Biol Phys. 2009; 75: 285-293https://doi.org/10.1016/j.ijrobp.2009.03.063
        • Acharya S.
        • Fischer-Valuck B.W.
        • Mazur T.R.
        • Curcuru A.
        • Sona K.
        • Kashani R.
        • et al.
        Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion.
        Int J Radiat Oncol Biol Phys. 2016; 96: 785-792https://doi.org/10.1016/j.ijrobp.2016.08.006
        • Lakosi F.
        • Gulyban A.
        • Ben-Mustapha Simoni S.
        • Viet Nguyen P.
        • Berkovic P.
        • Noël M.
        • et al.
        Feasibility evaluation of prone breast irradiation with the Sagittilt© system including residual-intrafractional error assessment.
        Cancer/Radiothérapie. 2016; 20: 776-782https://doi.org/10.1016/j.canrad.2016.05.014
        • Ricotti R.
        • Ciardo D.
        • Fattori G.
        • Leonardi M.C.
        • Morra A.
        • Dicuonzo S.
        • et al.
        Intra-fraction respiratory motion and baseline drift during breast Helical Tomotherapy.
        Radiother Oncol. 2017; 122: 79-86https://doi.org/10.1016/j.radonc.2016.07.019
        • de Senneville B.D.
        • Mougenot C.
        • Moonen C.T.W.
        Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound.
        Magn Reson Med. 2007; 57: 319-330https://doi.org/10.1002/mrm.21124
        • Liney G.P.P.
        • Whelan B.
        • Oborn B.
        • Barton M.
        • Keall P.
        MRI-Linear Accelerator Radiotherapy Systems.
        Clin Oncol. 2018; 30: 686-691https://doi.org/10.1016/j.clon.2018.08.003
        • Uijtewaal P.
        • Borman P.T.S.
        • Woodhead P.L.
        • Hackett S.L.
        • Raaymakers B.W.
        • Fast M.F.
        Dosimetric evaluation of MRI-guided multi-leaf collimator tracking and trailing for lung stereotactic body radiation therapy.
        Med Phys. 2021; 48: 1520-1532https://doi.org/10.1002/mp.14772